Diamond H 43ER105B1 Energy Regulator
Conversion chart
This part replaces the energy regulators listed below. Remove the connections
from the old control one by one and use the chart to identify the correct terminal on the new 43ER105B1 energy
regulator.
Make
Code
Signal
Live
Element 1
Element 2
Neutral
Diamond H
43ER105B1
S2 (Link S1 - P1)
P1
2
P2
4
Diamond H
33ER3..
S
P1
2
4
P2
Diamond H
23ER3..
PILOT
LINE
LOAD A
LOAD B
NEUT
Sunvic
TYJ 08 T
PILOT
LINE
LOAD A
LOAD B
NEUT
Sunvic
TYJ 6805
PILOT
LINE
LOAD A
LOAD B
NEUT
Turnright
19-1213
5
1
4
3
2
Turnright
20-1213
5
1
4
3
2
Turnright
RC 1213
P/L
LIVE
LOAD A
LOAD B
NEUTRAL
This information is provided as-is. No
responsibility is accepted for errors or omissions.
All parts must be fitted by a competent person with the
appliance disconnected from the mains supply. Precautions should be taken against possible injury from sharp edges.
Once the repair is complete the appliance must be tested to the latest electrical safety standards before reconnecting
to the mains supply.