Diamond H 43ER105B1 Energy Regulator
Conversion chart

Buy 43ER105B1 at Timms.biz

This part replaces the energy regulators listed below. Remove the connections from the old control one by one and use the chart to identify the correct terminal on the new 43ER105B1 energy regulator.
  Make Code Signal Live Element 1 Element 2 Neutral  
  Diamond H 43ER105B1 S2 (Link S1 - P1) P1 2 P2 4  
  Diamond H 33ER3.. S P1 2 4 P2  
  Diamond H 23ER3.. PILOT LINE LOAD A LOAD B NEUT  
  Sunvic TYJ 08 T PILOT LINE LOAD A LOAD B NEUT  
  Sunvic TYJ 6805 PILOT LINE LOAD A LOAD B NEUT  
  Turnright 19-1213 5 1 4 3 2  
  Turnright 20-1213 5 1 4 3 2  
  Turnright RC 1213 P/L LIVE LOAD A LOAD B NEUTRAL  

 

 

This information is provided as-is. No responsibility is accepted for errors or omissions.

 
 
All parts must be fitted by a competent person with the appliance disconnected from the mains supply. Precautions should be taken against possible injury from sharp edges. Once the repair is complete the appliance must be tested to the latest electrical safety standards before reconnecting to the mains supply.
 
   (c) 2008 MGS