Diamond H 41ER110B1 Energy Regulator
Conversion chart

Buy 41ER110B1 at Timms.biz

This part replaces the energy regulators listed below. Remove the connections from the old control one by one and use the chart to identify the correct terminal on the new 41ER110B1 energy regulator.
  Make Code Signal Live Element Neutral  
  Diamond H 41ER110B1 P2 (Link 4 - P1) P1 2 4A  
  Diamond H 31ER1.. S P1 2 P2  
  Diamond H 21ER1.. PILOT LINE LOAD NEUT  
  Diamond H 20ER1..   LINE LOAD NEUT  
  Sunvic TYJ 01 B   LINE LOAD NEUTRAL  
  Sunvic TYJ 02 B PILOT LINE LOAD NEUTRAL  
  Sunvic TYJ 6201 PILOT LINE LOAD NEUTRAL  
  Sunvic TYJ 6202   LINE LOAD NEUTRAL  
  Sunvic TYJ 6303 PILOT LINE LOAD NEUTRAL  
  Turnright 19-1103   4 1 2  
  Turnright 19-1113 3 1 4 2  
  Turnright 20-1103   4 1 2  
  Turnright 20-1113 3 1 4 2  
  Turnright RC 1103   LIVE LOAD A NEUTRAL  
  Turnright RC 1113 P/L LIVE LOAD A NEUTRAL  

 

 

This information is provided as-is. No responsibility is accepted for errors or omissions.

 
 
All parts must be fitted by a competent person with the appliance disconnected from the mains supply. Precautions should be taken against possible injury from sharp edges. Once the repair is complete the appliance must be tested to the latest electrical safety standards before reconnecting to the mains supply.
 
   (c) 2008 MGS