Diamond H 41ER110B1 Energy Regulator
Conversion chart
This part replaces the energy regulators listed below. Remove the connections
from the old control one by one and use the chart to identify the correct terminal on the new 41ER110B1 energy
regulator.
Make
Code
Signal
Live
Element
Neutral
Diamond H
41ER110B1
P2 (Link 4 - P1)
P1
2
4A
Diamond H
31ER1..
S
P1
2
P2
Diamond H
21ER1..
PILOT
LINE
LOAD
NEUT
Diamond H
20ER1..
LINE
LOAD
NEUT
Sunvic
TYJ 01 B
LINE
LOAD
NEUTRAL
Sunvic
TYJ 02 B
PILOT
LINE
LOAD
NEUTRAL
Sunvic
TYJ 6201
PILOT
LINE
LOAD
NEUTRAL
Sunvic
TYJ 6202
LINE
LOAD
NEUTRAL
Sunvic
TYJ 6303
PILOT
LINE
LOAD
NEUTRAL
Turnright
19-1103
4
1
2
Turnright
19-1113
3
1
4
2
Turnright
20-1103
4
1
2
Turnright
20-1113
3
1
4
2
Turnright
RC 1103
LIVE
LOAD A
NEUTRAL
Turnright
RC 1113
P/L
LIVE
LOAD A
NEUTRAL
This information is provided as-is. No
responsibility is accepted for errors or omissions.
All parts must be fitted by a competent person with the
appliance disconnected from the mains supply. Precautions should be taken against possible injury from sharp edges.
Once the repair is complete the appliance must be tested to the latest electrical safety standards before reconnecting
to the mains supply.